Exophiala is detected rapidly and automatically by MicroBio μ3D microbiological test system with MicroBio PDA.

Exophiala, black mold, can be detected reliably, rapidly and automatically !

Exophiala (black mold) is detected automatically and rapidly ! [Reliable]

マイクロバイオμ3D 全自動 迅速 微生物検出装置

mold, Exophiala detection, MicroBio μ3D fully automated rapid microbial detection system     MicroBio μ3D fully automated rapid microbial detection system

 

 

Just set the PDA agar medium plate and start.

(We recommend MicroBio PDA.)

 

 

Among molds and fungi, Exophiala is said to be detected hard and is the troublesome mold that contaminates such product as beverages and daily necessities, causing quality problem.

 

Potato dextrose agar (PDA) medium is commonly used in the industry as the main medium for mold detection, but exophiala rarely grows on PDAs, so normal PDA has difficulty to detect exophiala. This is one of the main causes of the problem.

 

Sabouraud dextrose agar medium or MicroBio PDA can be used for reliable detection.
If you use this medium for inspection of the exophiala contamination with MicroBio μ3D AutoScanner that is a fully automated microbial detection system, you can realize how easy it is to detect this troublesome mold. You can say the same for membrane filter method.


 【Exophiala】 Detection Comparison of media: PDA, GPLP, Sabouraud Dextrose

The following is the detection test data of MicroBio μ3D AutoScanner for thedetection of exophilia on agar medium of PDA, GPLP, and Sabouraud dextrose.
As a result, it was confirmed that Sabouraud dextrose medium supports thegrowth of Exophilia better than PDA medium.
We are conducting comparative studies using graphs, but it is said that it isbetter to have a large number of samples in order to obtain a standarddistribution (bell shape), so that the sample should have a bacterial count of1,000 cells / ml or more.

 

The same sample of Exophiala .jeanselmei was added to each medium. However,as a result of culturing, PDA detected no colony.

 

 

 

PDA (Potato Dextrose) Agar media

Composition

( PDA39.0g /  

water 1litter )

Potato infusion(4.0g),
Dextrose(20.0g),
Agar(15.0g)

Species strain Exophiala .jeanselmei(NBRC6858)

Sample

about1000-1500 cells / ml

     ※With PDA, Exophiala detection becomes false negative.

 

 

 

 

 

GPLP (Glucose Peptone Agar with Lecithin & Polysorbate) Agar media

Composition

( / water 1litter )

Yeast extract (2.0g), Casein Peptone(5.0g),
Gulcose(20.0g), Agar (15.0g), Magnesium sulfate(0.5g), Potassium dihydrogen phosphate(1.0g), lecithin(15.0g), 
Polysorbate(807g)

Species strain Exophiala .jeanselmei(NBRC6858)

Sample

about1000-1500 cells / ml

 

 

First imageLast image

First image   Last image

 

 

 

Sabouraud Dextrose Agar media

Composition

( / water 1litter )

Animal tissue-Pepsin digestion peptone(5.0g),        casein-Sui digestion peptone(5.0g),Gulcose(40.0g),
agar(15.0g

Species strain Exophiala .jeanselmei(NBRC6858)

Sample

about1000-1500 cells / ml

 

 

サExophiala detection first imege  Exophiala detection last image

First image    Last image

 

 

 

MicroBio PDA

Composition

( / water 1litter )

PDA modified
Species strain Exophiala .jeanselmei(NBRC6858)

Sample

about1000-1500 cells / ml

 

 

MicroBio PDA modified, first image  MicroBio PDA modified, last image

First image    Last image

Related Page

Virus and macrophage plaques are quantifed accurately.
Virus infected cells form plaques, and macrophage preyed bacteria form plaques. The plaque assay is a standard biological assay that counts and quantifies this plaque. MicrroBio μ3D collects data on the process of plaque formation during culture, allowing accurate plaque counting.
[Rapid Coliform Detection]
Coliform is detected with a pour plate of 2ml milk-sample automatically !
Traditional pour-plate method is used for the detection of coloform in seemingly impossible 2ml of milk-sample. Coliform can be detected faster in real time automatically by MicroBio μ3D AutoScanner.
[Coliform Negative Test]
Reliable coliform negative test is performed rapidly !
Nothing happens, but Negative is determined rapidly. Put a sample in it and incubate it. Microbiological test can be fully automated by Biomatic VDCS.
[Rapid Total Viable Count]
MicroBio µ3D automatically and rapidly enumerates Total Viable Count (TVC) of microorganisms on 100 plates being incubated at the same time.
MicroBio µ3D AutoScanner automatically, rapidly and precisely enumerates Total Viable Count (TVC) of microorganisms on 100 plates at the same time while the Standard Plate Count media plates are being incubated. The example is the case of cut vegetable mix sample.
[Detect coliform and E. coli]
The presence of E. coli is checked after coliform is detected.
The presence of E. coli is checked by applying UV light to the SensiMedia for letting blue fluorescence emission after coliform is detected.
[Membrane Filter Method]
Membrane filter method is fully automated as a rapid microbiological test method.
Each plate can be conditioned to anaerobic.
Membrane filter method is fully automated as a rapid microbiological test method. Each agar media plate with a filter can also be conditioned to anaerobic atmosphere.
[Automated Mold Detection]
Mold colonies are detected and counted rapidly and full automatically.
Mold (fungi) and yeast colonies are detected and enumerated rapidly and automatically by MicroBio µ3D AutoScanner. The MicroBio PDA performs well for mold culturing.
[Alicyclobacillus Detection]
Rapid Alicyclobacillus detection made easy at high temperature and low pH.
A rapid detection kit is available. (e.g.) Alicyclobacillus in a sugar syrup sample can be screened for Alicyclobacillus and then checked for guaiacol production to confirm the presence of live A. acidoterrestris.
[Salmonella Detection]
Rapid salmonella detection is easy for liquid, powder or solid sample.
Rapid salmonella detection is easy for liquid, powder or solid sample. SensiMedia takes any form of sample: shape, color, form.
[Auto-Anaerobe Detection]
Anaerobes are detected faster and automatically, including anaerobes grow at high temperature.
Anaerobes such as Lactobacillus or Clostridium are detected rapidly and automatically by MicorBio µ3D microbiological test system.
[Auto-Salmonella Detection]
Salmonella detection can be accelerated and automated.
Salmonella is detected rapidly and automatically by using MicroBio μ3D system with MicroBio Salmonella agar media, PPM001.
[Aerobe (mold) Detection]
Aerobes such as mold can be detected faster and easily.
With SensiMedia aerobic detection kit, aerobes such as mold canbe detected faster and easily.
[Auto-Clostridium Detection]
Anaerobe detection is validated by Clostridium sporogenes as standard species.
Clostridium in anaerobic atmosphere is detected rapidly and automatically by MicroBio µ3D microbiological test system.
[Microbial Property Characterization]
It is an example of characterization performed on cocoa antimicrobial property.
For it is said that cocoa has antibacterial property, characterization was perfermed to find out how effective the property is, using a microbial growth graph.
[Food poisoning microbe]
There are various rapid detection kits for food poisoning microbes !
SensiMedia is microbial detection kit to test samples and is available to detect food poisoning microbes: Salmonella, Staphylococcus aureus, O157, Bacillus cereus, Listeria.

home