Salmonella detection is accelerated and automated !

Salmonella detection is accelerated and automated !

Salmonella detection can be accelerated and automated !

MicroBio µ3D

Salmonella agar mediaSalmonella automated detection, MicroBio µ3D

Set plates and start a test !

culture media

 

PPM001 Agar Media for Salmonella detection

Citrobacter freundii produces hydrogen sulfide like Salmonella does. Therefore, it becomes hard to distinguish C. freundii colonies from Salmonella colonies since Salmonella agar media detects hydrogen sulfide production making formed colonies black even though the growth of C. freundii is suppressed well. In our media, L-lysine and pH indicator are formulated to make agar substrate reddish purple for colony surroundings of Salmonella and green for colony surroundings of others, for easier judgement.

 

Using MicroBio Salmonella agar media, PPM001, Salmonella is detected easily. If this media is used by MicroBio µ3D, detection becomes even more easier and faster.

Salmonella is detected on PPM001 culture media

Salmonella entiritidis detection

 

Test System

MicroBio µ3D AutoScanner

Species strain

Salmonella entiritidis (ATCC13076)

Agar Media

Salmonella agar media (MicroBio PPM001)

Sample

0.1ml spread plate

Incubation

40ºC, 24hr

Detection Result

42 colonies at 15hr

 

Salmonella entiritidis Colony Count Graph

 

 

 

Salmonella typhimurium detection

 

Test System

MicroBio µ3D AutoScanner

Species strain

Salmonella typhimurium (ATCC14028)

Agar Media

Salmonella agar media (MicroBio PPM001)

Sample

0.1ml spread plate

Incubation

40ºC, 24hr

Detection Result

35 colonies at 17hr

 

Salmonella typhimurium 検出グラフ

Klebsiella is detected on PPM001 culture media

Klebsiella pneumoniae detection

 

Test System

MicroBio µ3D AutoScanner

Species strain

Klebsiella pneumoniae (ATCC33495)

Agar Media

Salmonella agar media (MicroBio PPM001)

Sample

0.1ml spread plate

Incubation

40ºC, 24hr

Detection Result

No Salmonella colony

 

Klebsiella pneumoniae 検出グラフ

When MicroBio Salmonella agar media, PPM001, is use and K. pneumoniae is detected, the colony surroundings become green color for easier judgement.

Related Page

Virus and macrophage plaques are quantifed accurately.
Virus infected cells form plaques, and macrophage preyed bacteria form plaques. The plaque assay is a standard biological assay that counts and quantifies this plaque. MicrroBio μ3D collects data on the process of plaque formation during culture, allowing accurate plaque counting.
[Rapid Coliform Detection]
Coliform is detected with a pour plate of 2ml milk-sample automatically !
Traditional pour-plate method is used for the detection of coloform in seemingly impossible 2ml of milk-sample. Coliform can be detected faster in real time automatically by MicroBio μ3D AutoScanner.
[Coliform Negative Test]
Reliable coliform negative test is performed rapidly !
Nothing happens, but Negative is determined rapidly. Put a sample in it and incubate it. Microbiological test can be fully automated by Biomatic VDCS.
[Rapid Total Viable Count]
MicroBio µ3D automatically and rapidly enumerates Total Viable Count (TVC) of microorganisms on 100 plates being incubated at the same time.
MicroBio µ3D AutoScanner automatically, rapidly and precisely enumerates Total Viable Count (TVC) of microorganisms on 100 plates at the same time while the Standard Plate Count media plates are being incubated. The example is the case of cut vegetable mix sample.
[Detect coliform and E. coli]
The presence of E. coli is checked after coliform is detected.
The presence of E. coli is checked by applying UV light to the SensiMedia for letting blue fluorescence emission after coliform is detected.
[Membrane Filter Method]
Membrane filter method is fully automated as a rapid microbiological test method.
Each plate can be conditioned to anaerobic.
Membrane filter method is fully automated as a rapid microbiological test method. Each agar media plate with a filter can also be conditioned to anaerobic atmosphere.
[Automated Mold Detection]
Mold colonies are detected and counted rapidly and full automatically.
Mold (fungi) and yeast colonies are detected and enumerated rapidly and automatically by MicroBio µ3D AutoScanner. The MicroBio PDA performs well for mold culturing.
[Alicyclobacillus Detection]
Rapid Alicyclobacillus detection made easy at high temperature and low pH.
A rapid detection kit is available. (e.g.) Alicyclobacillus in a sugar syrup sample can be screened for Alicyclobacillus and then checked for guaiacol production to confirm the presence of live A. acidoterrestris.
[Salmonella Detection]
Rapid salmonella detection is easy for liquid, powder or solid sample.
Rapid salmonella detection is easy for liquid, powder or solid sample. SensiMedia takes any form of sample: shape, color, form.
[Exophiala Detection]
Exophiala, black mold, is detected reliably, rapidly and automatically.
Exophiala is detected rapidly and automatically by MicroBio µ3D microbiological test system with MicroBio PDA.
[Auto-Anaerobe Detection]
Anaerobes are detected faster and automatically, including anaerobes grow at high temperature.
Anaerobes such as Lactobacillus or Clostridium are detected rapidly and automatically by MicorBio µ3D microbiological test system.
[Aerobe (mold) Detection]
Aerobes such as mold can be detected faster and easily.
With SensiMedia aerobic detection kit, aerobes such as mold canbe detected faster and easily.
[Auto-Clostridium Detection]
Anaerobe detection is validated by Clostridium sporogenes as standard species.
Clostridium in anaerobic atmosphere is detected rapidly and automatically by MicroBio µ3D microbiological test system.
[Microbial Property Characterization]
It is an example of characterization performed on cocoa antimicrobial property.
For it is said that cocoa has antibacterial property, characterization was perfermed to find out how effective the property is, using a microbial growth graph.
[Food poisoning microbe]
There are various rapid detection kits for food poisoning microbes !
SensiMedia is microbial detection kit to test samples and is available to detect food poisoning microbes: Salmonella, Staphylococcus aureus, O157, Bacillus cereus, Listeria.

home