The presence of E. coli is checked after coliform is detected !

The presence of E. coli is checked after coliform is detected !

The presence of E. coli is checked after coliform is detected !

coliform,E coli,rapid,detection,microbiological,test,

 

coliform,E coli,rapid,detection,microbiological,test, coliform,E coli,rapid,detection,microbiological,test,

Add sample and incubate it !

 

Using E. coli detection kit, when coliform is detected, the color of CO2 sensor turns into yellow.
Then, if E. coli exists at the same time, the broth emits light-blue fluorescence under Ultra-Violet excitation light. When the color of CO2 sensor remains dark blue, no coliform of the kind exists in the sample. If sensor turns into yellow and if the broth does not emit fluorescence under Ultra-Violet light, then coliform is detected, but no E. coli exists in the sample.

 

SensiMedia SM microbial detection kitSensiMedia SM trade mark   (1ml sample)

SM010 E. coli detection

Add 1ml of sample to SensiMedia SM010 and incubate it at 35 ℃ instead of 43℃. When the sensor turns into yellow, coliform is detected. Then, check for E. coli presence by UV light.

 

SensiMedia SML microbial detection kitSensiMedia SML trade mark   (5ml sample)

SML010 E. coli detection

Add 5ml of sample to SensiMedia SML010 and incubate it at 35 ℃ instead of 43℃. When the sensor turns into yellow, coliform is detected. Then, check for E. coli presence by UV light.

 

E coli detection


Related Page

Virus and macrophage plaques are quantifed accurately.
Virus infected cells form plaques, and macrophage preyed bacteria form plaques. The plaque assay is a standard biological assay that counts and quantifies this plaque. MicrroBio μ3D collects data on the process of plaque formation during culture, allowing accurate plaque counting.
[Rapid Coliform Detection]
Coliform is detected with a pour plate of 2ml milk-sample automatically !
Traditional pour-plate method is used for the detection of coloform in seemingly impossible 2ml of milk-sample. Coliform can be detected faster in real time automatically by MicroBio μ3D AutoScanner.
[Coliform Negative Test]
Reliable coliform negative test is performed rapidly !
Nothing happens, but Negative is determined rapidly. Put a sample in it and incubate it. Microbiological test can be fully automated by Biomatic VDCS.
[Rapid Total Viable Count]
MicroBio µ3D automatically and rapidly enumerates Total Viable Count (TVC) of microorganisms on 100 plates being incubated at the same time.
MicroBio µ3D AutoScanner automatically, rapidly and precisely enumerates Total Viable Count (TVC) of microorganisms on 100 plates at the same time while the Standard Plate Count media plates are being incubated. The example is the case of cut vegetable mix sample.
[Membrane Filter Method]
Membrane filter method is fully automated as a rapid microbiological test method.
Each plate can be conditioned to anaerobic.
Membrane filter method is fully automated as a rapid microbiological test method. Each agar media plate with a filter can also be conditioned to anaerobic atmosphere.
[Automated Mold Detection]
Mold colonies are detected and counted rapidly and full automatically.
Mold (fungi) and yeast colonies are detected and enumerated rapidly and automatically by MicroBio µ3D AutoScanner. The MicroBio PDA performs well for mold culturing.
[Alicyclobacillus Detection]
Rapid Alicyclobacillus detection made easy at high temperature and low pH.
A rapid detection kit is available. (e.g.) Alicyclobacillus in a sugar syrup sample can be screened for Alicyclobacillus and then checked for guaiacol production to confirm the presence of live A. acidoterrestris.
[Salmonella Detection]
Rapid salmonella detection is easy for liquid, powder or solid sample.
Rapid salmonella detection is easy for liquid, powder or solid sample. SensiMedia takes any form of sample: shape, color, form.
[Exophiala Detection]
Exophiala, black mold, is detected reliably, rapidly and automatically.
Exophiala is detected rapidly and automatically by MicroBio µ3D microbiological test system with MicroBio PDA.
[Auto-Anaerobe Detection]
Anaerobes are detected faster and automatically, including anaerobes grow at high temperature.
Anaerobes such as Lactobacillus or Clostridium are detected rapidly and automatically by MicorBio µ3D microbiological test system.
[Auto-Salmonella Detection]
Salmonella detection can be accelerated and automated.
Salmonella is detected rapidly and automatically by using MicroBio μ3D system with MicroBio Salmonella agar media, PPM001.
[Aerobe (mold) Detection]
Aerobes such as mold can be detected faster and easily.
With SensiMedia aerobic detection kit, aerobes such as mold canbe detected faster and easily.
[Auto-Clostridium Detection]
Anaerobe detection is validated by Clostridium sporogenes as standard species.
Clostridium in anaerobic atmosphere is detected rapidly and automatically by MicroBio µ3D microbiological test system.
[Microbial Property Characterization]
It is an example of characterization performed on cocoa antimicrobial property.
For it is said that cocoa has antibacterial property, characterization was perfermed to find out how effective the property is, using a microbial growth graph.
[Food poisoning microbe]
There are various rapid detection kits for food poisoning microbes !
SensiMedia is microbial detection kit to test samples and is available to detect food poisoning microbes: Salmonella, Staphylococcus aureus, O157, Bacillus cereus, Listeria.

home
Qualitative Quantitative Biomatic VDCS MicroBio μ3D Test Kit Culture Media Contact Company