Anaerobes are detected faster and automatically, inclusing anaerobes grow at high temperature !

Anaerobes are detected faster and automatically, inclusing anaerobes grow at high temperature !

Anaerobes are detected rapidly and automatically !

MicroBio μ3D trade mark

anaerobic conditioned plate  MicroBio μ3D rapid microbial detection system

Set anaerobic plates and start a test.

 

Time-lapse monitoring while incubating anaerobic conditioned plates can be performed by MicroBio µ3D system. We provide anaerobic conditioning kit that makes each plate in anaerobic condition, including a plate that a membrane filter is placed on the surface of agar media. Therefore, now, anaerobe detection is fully automated for rapid detection. Anaerobic plates are treated as same as ordinary plates so that a test can be run in mixed mode of aerobic and anaerobic.

 

Deoxygenating Method

An anaerobic conditioning kit produces deoxygenated condition for each agar plate, substituting oxygen with carbon dioxide inside of the plate.

 

anaerobic conditioning kit

 

Pouch Method

Anaerobe detection can be performed by incubating a pouch that contains poured thioglycolate agar media mixed with sample. Placing pouches into slots of a tray and setting the tray into MicroBio µ3D, fully automated rapid anaerobe detection can be performed.

 

パウチ


Thermoanaerobacter thermohydrosulfuricus Dectection

It used to take for the traditional method about one week to detect Thermoanaerobacter that causes product quality problem in food industry. Using MicroBio µ3D with anaerobic conditioned media plate, the anaerobes are detected much faster.
Clostridium thermohydrosulfuricum is a synonym of Thermoanaerobacter thermohydrosulfuricus.

Test System

MicroBio µ3D AutoScanner

Species strain

Thermoanaerobacter thermohydrosulfuricus (ATCC35045)

Agar Media

Clostridial Agar Media

Sample

Poured in round pouch

Incubation

60ºC, 48h

Detection Result

18 colonies at 48h, 16 colonies detection nearly completed at 24h

 

48hr

Plate Image

Count Marker

plate image of Thermoanaerobacter thermohydrosulfuricus at 48h

Count marker of Thermoanaerobacter thermohydrosulfuricus at48h

graph of Thermoanaerobacter thermohydrosulfuricus at 48h

The above graph with plate image can be displayed during a test. The automatic detection was nearly completed at 24hr for this example, detecting 16 colonies.

Thermoanaerobacter mathranii Dectection

Thermoanaerobacter mathranii is also detected by MicroBio µ3D much faster and automatically.

Test System

MicroBio µ3D AutoScanner

Species strain

Thermoanaerobacter mathranii (DSM11426)

Agar Media

Clostridial Agar Media

Sample

Poured in round pouch

Incubation

60ºC, 64h

Detection Result

65 colonies at 50h, 64 colonies detection nearly completed at 41h

 

48hr

Plate Image

Count Marker

sample pouch image of Thermoanaerobacter mathranii

Count marker of Thermoanaerobacter mathranii

graph of Thermoanaerobacter mathranii 

The above graph with plate image can be displayed during a test. The automatic detection was nearly completed at 41hr for this example, detecting 64 colonies.

Related Page

Virus and macrophage plaques are quantifed accurately.
Virus infected cells form plaques, and macrophage preyed bacteria form plaques. The plaque assay is a standard biological assay that counts and quantifies this plaque. MicrroBio μ3D collects data on the process of plaque formation during culture, allowing accurate plaque counting.
[Rapid Coliform Detection]
Coliform is detected with a pour plate of 2ml milk-sample automatically !
Traditional pour-plate method is used for the detection of coloform in seemingly impossible 2ml of milk-sample. Coliform can be detected faster in real time automatically by MicroBio μ3D AutoScanner.
[Coliform Negative Test]
Reliable coliform negative test is performed rapidly !
Nothing happens, but Negative is determined rapidly. Put a sample in it and incubate it. Microbiological test can be fully automated by Biomatic VDCS.
[Rapid Total Viable Count]
MicroBio µ3D automatically and rapidly enumerates Total Viable Count (TVC) of microorganisms on 100 plates being incubated at the same time.
MicroBio µ3D AutoScanner automatically, rapidly and precisely enumerates Total Viable Count (TVC) of microorganisms on 100 plates at the same time while the Standard Plate Count media plates are being incubated. The example is the case of cut vegetable mix sample.
[Detect coliform and E. coli]
The presence of E. coli is checked after coliform is detected.
The presence of E. coli is checked by applying UV light to the SensiMedia for letting blue fluorescence emission after coliform is detected.
[Membrane Filter Method]
Membrane filter method is fully automated as a rapid microbiological test method.
Each plate can be conditioned to anaerobic.
Membrane filter method is fully automated as a rapid microbiological test method. Each agar media plate with a filter can also be conditioned to anaerobic atmosphere.
[Automated Mold Detection]
Mold colonies are detected and counted rapidly and full automatically.
Mold (fungi) and yeast colonies are detected and enumerated rapidly and automatically by MicroBio µ3D AutoScanner. The MicroBio PDA performs well for mold culturing.
[Alicyclobacillus Detection]
Rapid Alicyclobacillus detection made easy at high temperature and low pH.
A rapid detection kit is available. (e.g.) Alicyclobacillus in a sugar syrup sample can be screened for Alicyclobacillus and then checked for guaiacol production to confirm the presence of live A. acidoterrestris.
[Salmonella Detection]
Rapid salmonella detection is easy for liquid, powder or solid sample.
Rapid salmonella detection is easy for liquid, powder or solid sample. SensiMedia takes any form of sample: shape, color, form.
[Exophiala Detection]
Exophiala, black mold, is detected reliably, rapidly and automatically.
Exophiala is detected rapidly and automatically by MicroBio µ3D microbiological test system with MicroBio PDA.
[Auto-Salmonella Detection]
Salmonella detection can be accelerated and automated.
Salmonella is detected rapidly and automatically by using MicroBio μ3D system with MicroBio Salmonella agar media, PPM001.
[Aerobe (mold) Detection]
Aerobes such as mold can be detected faster and easily.
With SensiMedia aerobic detection kit, aerobes such as mold canbe detected faster and easily.
[Auto-Clostridium Detection]
Anaerobe detection is validated by Clostridium sporogenes as standard species.
Clostridium in anaerobic atmosphere is detected rapidly and automatically by MicroBio µ3D microbiological test system.
[Microbial Property Characterization]
It is an example of characterization performed on cocoa antimicrobial property.
For it is said that cocoa has antibacterial property, characterization was perfermed to find out how effective the property is, using a microbial growth graph.
[Food poisoning microbe]
There are various rapid detection kits for food poisoning microbes !
SensiMedia is microbial detection kit to test samples and is available to detect food poisoning microbes: Salmonella, Staphylococcus aureus, O157, Bacillus cereus, Listeria.

home
Qualitative Quantitative Biomatic VDCS MicroBio μ3D Test Kit Culture Media Contact Company